Назад к списку Учебники

Promyshlennyy 10G Media Konverter SPM-ETGX-PXT Rukovodstvo po Produktu - S-Opto

SOPTO

2026-10-19 19 просмотров
Promyshlennyy 10G Media Konverter SPM-ETGX-PXT Rukovodstvo po Produktu - S-Opto

Promyshlennyy 10G Media Konverter SPM-ETGX-PXT: Polnoye Rukovodstvo po Produktu

1 Opisanie Produkta

SPM-ETGX-PXT - eto samyy kompaktnyy promyshlennyy 10G Ethernet media konverter Sopto, obespechivayushchiy preobrazovaniye sredy 1 port RJ45 med ↔ 1 port SFP+ optovolokno. Mednyy port avtomaticheski adaptiruyetsya k 100M/1G/2.5G/5G/10G BASE-T, v to vremya kak opticheskiy port imeyet s"yemnyy slot SFP+ 10G; alyuminiyevyy splav korpusa IP40 bez ventilyatora, rabochaya temperatura ot -40°C do +75°C, podderzhivayet dvoynoye rezervnoye pitaniye 12-48VDC, podderzhivayet montazh na DIN-reyku i nastennyy montazh, podkhodit dlya rasshireniya 10G seti v zhestkikh promyshlennykh usloviyakh, takikh kak zavody i naruzhnyye shkafy. Propusknaya sposobnost' arkhitektury kommutatsii vsego ustroystva sostavlyayet 20Gbps, peredacha na skorosti linii bez blokirovki, rezhim obrabotki store-and-forward, podderzhivayet jumbo freymy do 16K, tablitsa MAC-adresov na 9K zapisey.

Fizicheskiye Parametry Ustroystva

  • Razmery: 95mm x 70mm x 30mm; Ves 0.25kg
  • MTBF: >200,000 chasov; Maksimnoye energopotrebleniye 5W
  • Sertifikaty: ISO9001, CE, RoHS, FCC, sootvetstvuyet polnym promyshlennym standartam immuniteta EMC (ESD/EFT/voloski i t.d.)

Komplekt Postavki

1 media konverter, komplekt dlya montazha na DIN-reyku, komplekt dlya nastennogo montazha, garantinyy talon; Opticheskiye moduli SFP+ neobkhodimo priobretat' otdel'no, upakovka ne vklyuchayet opticheskiye moduli.

2 Ustanovka Oborudovaniya

2.1 Montazh Ustroystva (Vybrat' Odin)

  1. Montazh na DIN-reyku: Vstav'te sootvetstvuyushchiy zashchimnyy klip v zadnyuyu chast' ustroystva, vertikal'no zakrepite na standartnoy DIN-35 reylke;
  2. Nastennyy Montazh: Ispol'zuyte komplekt dlya nastennogo montazha, zakrepite ustroystvo na ploskosti shkafa/steny s pomoshch'yu predvaritel'no prosverlennykh montazhnykh otverstiy na korpuse;
Primechaniye: Ustroystvo ispol'zuyet okhlazhdeniye bez ventilyatora. Ostav'te ventilyatsionnyy zazor >=15mm vokrug korpusa. Ne blokiruyte i ne zakryvayte radiatornyye plastiny na korpuse dlya obespecheniya nadezhnoy raboty v shirokom diapazone temperatur ot -40°C do +75°C.

2.2 Podklyucheniye Pitaniya

Ustroystvo ispol'zuyet 4-kontaktnyy klemmnyy blok, podderzhivaya dvoynoye rezervnoye vvodnoye pitaniye 12-48VDC, s zashchitoy ot obratnoy polyarnosti i zashchitoy ot peregruzki vvoda s avtomaticheskim vosstanovleniyem.

  • Podderzhivayetsya odno istochnik pitaniya, no rekomenduyetsya ispol'zovat' dva nezavisimykh istochnika postoyannogo toka dlya rezervirovaniya v promyshlennykh usloviyakh. Yesli odin vykhodit iz stroya, drugoy podderzhivayet rabotu ustroystva;
  • NE podklyuchayte AC220V neposredstvenno k klemmam; klemmy prinimayut tol'ko 12-48V DC;
  • Zazemleniye metallicheskogo korpusa rekomenduyetsya dlya uluchsheniya kharakteristik immuniteta EMC.

2.3 Podklyucheniye Interfeysa

(1) Mednyy Port RJ45 (TP)

Mednyy port podderzhivayet Auto-MDI/MDI-X s avtomaticheskim krossoverom, chto ustranyayet neobkhodimost' razlichat' pryamyye i krossovernyye kabeli. Vybor kablya dolzhen strogo sootvetstvovat' trebovaniyam skorosti:

Skorost'Minimal'naya Spetsifikatsiya KablyaMaksimal'naya Dal'nost' Peredachi
10G BASE-TCat6A / Cat7100m
5G BASE-TCat6 / Cat6A / Cat7100m
2.5G/1GCat5e ili vyshe100m
100MCat5 ili vyshe100m
Maksimal'naya dal'nost' kablya sostavlyayet 100 metrov. Podkhodyat kak neekranirovannyye kabeli UTP, tak i ekranirirovannyye vitoye pary EIA/TIA-568 100Ω STP.

(2) Opticheskiy Port SFP+ (FX)

  1. Nadente antistaticheskuyu zashchitu, vstav'te sootvetstvuyushchiy opticheskiy modul SFP+ 10GBASE-X (SR/LR/BX i t.d. 10G SFP+, ne sovmestim s Gigabit SFP);
  2. Podklyuchite opticheskiye patch-kabeli: mnogomodovoye optovolokno 50/125um do 300m; odnomodovoye optovolokno 9/125um do 80km. Krossovernoye podklyucheniye portov TX/RX;
  3. Vsegda zakryvayte neispol'zuyemyye opticheskiye porty pyl'nikami, chtoby izbezhat' povrezhdeniya opticheskikh komponentov pyl'yu.
Podskazka: Moduli SFP+ dolzhny sootvetstvovat' tipu optovolokna. Mnogomodovyye moduli trebuyut mnogomodovogo optovolokna, odnomodovyye moduli trebuyut odnomodovogo optovolokna, inache svyaz' ne budet rabotat'.

3 Opisanie DIP-Pereklyuchatelya

4-polozhnyye DIP-pereklyuchateli SW1-SW4 vse rezervirovany na zavode bez predustanovlennykh funktsiy. Funktsii DIP-pereklyuchateley podderzhivayut nastroyku kliyenta. Zavodskiye sostoyaniya ON/OFF rezervirovany. Normal'nyye proekty ne trebuyut nastroyki DIP-pereklyuchateley, sokhranyayte nastroyki po umolchaniyu. Dlya nastroyki funktsiy obratites' k tekhnicheskoy komande Sopto dlya nastroyki proshivki i oborudovaniya.

4 Diagnostika Svetovykh Indikatorov

LEDMetkaOpisanie Sostoyaniya
PWRSostoyaniye PitaniyaPostoyanno: Pitaniye v poryadke; Vyklyucheno: Net pitaniya / pitaniye nenormal'no; Dvoynoye rezervnoye pitaniye, PWR zagorayetsya, kogda lyuboy istochnik pitaniya dostupen
TPSostoyaniye Mednogo Porta EthernetPostoyanno: Svyaaz' porta RJ45 UP; Migayet: Peredacha/priyem dannykh; Vyklyucheno: Kabel' ne podklyuchen, udalennyy konets bez pitaniya
FXSostoyaniye Opticheskogo Porta SFP+Postoyanno: Opticheskaya svyaaz' uspeshno ustanovlena; Migayet: Opticheskiy port peredayet/prinimayet dannyye; Vyklyucheno: Opticheskiy modul ne raspoznat, optovolokno otklyucheno, net signala ot udalennogo kontsa
Bystroye Ustraneniye Neispravnostey:
  1. PWR ne svetitsya → Prover'te napryazheniye i polyarnost' klemmy DC, podtverdite vvod 12-48V DC; Ustroystvo imeyet vstroennuyu zashchitu ot obratnoy polyarnosti, obratnoye podklyucheniye ne povredit ustroystvo, no ono ne zapustitsya;
  2. LED TP ne svetitsya: Prover'te klass kablya, dlinu i vkluchen li udalennyy port; Dlya skorosti 10G vsegda ispol'zuyte kvalifitsirovannyy kabel' Cat6A;
  3. LED FX ne svetitsya: Podtverdite, chto SFP+ - eto modul' SFP+ 10G, prover'te napravleniye peredachi/priyema optovolokna, prover'te, ne prevyshayet li dal'nost' optovolokna nominal'nuyu dal'nost' modulya.

5 Parametry Protokola i Peredachi

  1. Sootvetstvuyet standartam IEEE: 802.3u/802.3ab/802.3bz/802.3ae, podderzhivayet EEE energoeffektivnyy Ethernet 802.3az; Upravleniye potokom polnogo dubleksa IEEE802.3x;
  2. Rezhim peregovorov: 100M/1G podderzhivayet avtomaticheskiye peregovory polu/polnogo dubleksa; 2.5G/5G/10G podderzhivayet tol'ko polnyy dupleks;
  3. Mekhanizm peredachi: Store-and-forward; Kommutatsionnaya matritsa 20Gbps; Podderzhivayet jumbo freymy 16K; Tablitsa MAC-adresov 9K s avtomaticheskim izucheniyem i sostareniyem adresov;
  4. Plug-and-play, ne trebuyetsya upravleniye konfiguratsiyey, rabotayet srazu posle vklyucheniya i podklyucheniya.

6 Obsluzhivaniye i Mery Predostorozhnosti

  1. Temperatura khraneniya ot -40°C do +85°C, ustroystvo ne dolzhno khranit'sya za predelami etogo diapazona; Rabochaya vlazhnost' 5-95% bez kondensatsii;
  2. Konstruktsiya bez ventilyatora zavisit ot alyuminiyevogo korpusa dlya rasseivaniya tepla, ne obertyvayte ustroystvo;
  3. V promyshlennykh usloviyakh s vysokimi elektromagnitnymi pomekhami ispol'zuyte ekranirirovannyye kabeli + nadezhnoye zazemleniye korpusa dlya uluchsheniya ustoychivosti k impul'sam i ESD;
  4. Ne podderzhivayet vykhod PoE, port RJ45 prednaznachen tol'ko dlya peredachi dannykh, ne mozhet pitat' kamery ili drugiya ustroystva;
  5. Model' zakaza: SPM-ETGX-PXT; Ne vklyuchayet opticheskiye moduli SFP+, opticheskiye moduli SFP+ 10G sootvetstvuyushchey dal'nosti dolzhny byt' vybrany otdel'no.

Теги

Похожие статьи

No image
Учебники

SPT-P2T13V3-40D Dvukhkanal'nyy 3G-SDI SFP Peredayushchiy Opticheskiy Modul' Tekhnicheskoye Rukovodstvo - S-Opto

Tekhnicheskoye rukovodstvo po dvukhkanal'nomu peredayushchemu opticheskomu modulyu SFP SPT-P2T13V3-40D, okhvatyvayushcheye printsipy produkta, apparatnuyu provodku, otladku vklyucheniya, diagnostiku DDM i ustraneniye neispravnostey. DFB-lazer 1310nm, peredacha 40km, podderzhka SD-SDI/HD-SDI/3G-SDI.

SOPTO SOPTO
2026-10-20 0
Практическое руководство по основам волоконно-оптической связи
Учебники

Практическое руководство по основам волоконно-оптической связи

Это инженерно-ориентированное техническое руководство, основанное на отраслевых стандартах ITU-T и TIA, без выдуманных параметров, подходит для блогов продуктов внешней торговли, документации по предварительным продажам и обучения инженерному делу. Охватывает классификацию волокна, основные компоненты, процесс сварки, проверку торцов, тестирование линии, потери и дисперсию, устранение неисправностей.

SOPTO SOPTO
2026-10-15 12
Полное руководство по оптическим трансиверам
Учебники

Полное руководство по оптическим трансиверам

Оптические трансиверы — сердце волоконно-оптических сетей, выполняющие преобразование сигналов. В руководстве рассмотрены принципы работы, ключевые параметры, классификация, маркировка и правила эксплуатации.

SOPTO SOPTO
2026-08-12 68